Programming 440i Timers
1. Set days of regeneration on Skipper Wheel.
- Pull all skipper pins outward (away from control).
- Rotate skipper wheel until day arrow points to
current day or number 1.
- Depress skipper pin(s) at day(s) for which regeneration
is desired.
2. Set the time of day.
- Grasp timer knob and pull outward.
- Rotate in either direction until the timer arrow
points to the actual time of day.
- Release timer knob.
Note: With the time of day properly set,
the conditioner will regenerate at about 2:30am. If you prefer
to have the unit regenerate at an earlier or later time, simply
set current time-of-day accordingly (e.g. to have the unit regenerate
at 4:30am- two hours later- set the clock two hours earlier than
the actual time of day.)
Note: The Timer Locking Pin should always
be horizontal during operation.

Programming 460i Timers
Plug the wall-mount transformer into a functioning
electrical outlet that is not controlled by a switch. Plug the
transformer into the transformer plug receptacle on the control.
Open the access door by pushing the raised tab on
the door toward the left while pulling the tab out.
Time of Day Settings
With the jumper on the set of pins next to the word
TIME, set the time of day to the closest hour by pressing the
black TIME SET button. PM hours are indicated by a light next
to the letters PM on the display window.
Note: The unit is factory set to regenerate
at 2:30am. If you prefer to have the unit regenerate at an earlier
or later time, simply set current time-of-day accordingly (e.g.
to have the unit regenerate at 4:30am- two hours later- set the
clock two hours earlier than the actual time of day.)
Note: The Timer Locking Pin should always
be horizontal during operation.